Characterization of pneumatically activated microvalves by measuring electrical conductance
Résumé
Accurate determination of the mechanical response of pneumatic activated microvalves is important for the optimization of a number of microlluidic elements. In the case of multi-layers PDMS devices, pneumatic activated valves are used in combination for pumping, mixing and other functionalities. In such devices, the mechanical response of a valve depends on the PDMS toughness, the membrane thickness as well as the detail of the channel configuration and the pressure applied in both flow and control channels. We describe characterization technique of a pneumatic activated valve based on conductance measurements of electrolytes in the microfluidic channel. We also show that the well calibrated microvalves can be used for the development of more complex functionalities such as high precision dose control of chemical solutions. (c) 2004 Elsevier B.V. All rights reserved.
Citer cet article
Galas, J., Studer, V., & Chen, Y. (2005). Characterization of pneumatically activated microvalves by measuring electrical conductance. Microelectron. Eng., 78-79(SI). https://doi.org/10.1016/j.mee.2004.12.016
@article{Galas2005_123,
author = {Galas, JC and Studer, V and Chen, Y},
year = {2005},
month = {1},
title = {Characterization of pneumatically activated microvalves by measuring electrical conductance},
journal = {Microelectron. Eng.},
publisher = {ELSEVIER SCIENCE BV},
volume = {78-79},
number = {SI},
address = {PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS},
abstract = {Accurate determination of the mechanical response of pneumatic activated microvalves is important for the optimization of a number of microlluidic elements. In the case of multi-layers PDMS devices, pneumatic activated valves are used in combination for pumping, mixing and other functionalities. In such devices, the mechanical response of a valve depends on the PDMS toughness, the membrane thickness as well as the detail of the channel configuration and the pressure applied in both flow and control channels. We describe characterization technique of a pneumatic activated valve based on conductance measurements of electrolytes in the microfluidic channel. We also show that the well calibrated microvalves can be used for the development of more complex functionalities such as high precision dose control of chemical solutions. (c) 2004 Elsevier B.V. All rights reserved.},
note = {30th International Conference on Micro and Nano Engineering, Rotterdam, NETHERLANDS, SEP 19-22, 2004},
url = {http://www.dx.doi.org/10.1016/j.mee.2004.12.016},
doi = {10.1016/j.mee.2004.12.016},
issn = {0167-9317},
}
TY - JOUR
AU - Galas, JC
AU - Studer, V
AU - Chen, Y
PY - 2005
DA - 2005/01/01
TI - Characterization of pneumatically activated microvalves by measuring electrical conductance
JO - Microelectron. Eng.
VL - 78-79
IS - SI
PB - ELSEVIER SCIENCE BV
SN - 0167-9317
AB - Accurate determination of the mechanical response of pneumatic activated microvalves is important for the optimization of a number of microlluidic elements. In the case of multi-layers PDMS devices, pneumatic activated valves are used in combination for pumping, mixing and other functionalities. In such devices, the mechanical response of a valve depends on the PDMS toughness, the membrane thickness as well as the detail of the channel configuration and the pressure applied in both flow and control channels. We describe characterization technique of a pneumatic activated valve based on conductance measurements of electrolytes in the microfluidic channel. We also show that the well calibrated microvalves can be used for the development of more complex functionalities such as high precision dose control of chemical solutions. (c) 2004 Elsevier B.V. All rights reserved.
DO - 10.1016/j.mee.2004.12.016
UR - http://www.dx.doi.org/10.1016/j.mee.2004.12.016
ER -