article · 01/01/2011
Prototyping of microfluidic systems using a commercial thermoplastic elastomer
Résumé
This article describes the fabrication of microfluidic networks (mu FNs) from a commercially available (styrene)-(ethylene/butylene)-(styrene) (SEBS) block copolymer (BCP). The unique combination of hard and elastomeric properties provided by this material promotes high-throughput replication of fluidic structures using thermoforming technologies, while retaining the advantage of quick and easy assembly via conformal contact, as commonly achieved for devices fabricated from poly(dimethylsiloxane (PDMS). We employ Versaflex CL30, which is optically transparent, available at low cost (e.g., \$2.50/Lbs), and likely to be compatible with a broad range of biological species. We demonstrate excellent fidelity in replication of fluidic structures using hot embossing lithography in conjunction with a photolithographically prepared Si/SU-8 master mold. Moreover, we introduce rapid prototyping of high-quality structures using an approach that we call soft thermoplastic lithography (STPL). Thanks to the rheological characteristics of the SEBS copolymer, STPL enables thermoforming on a heated master at temperatures around 170A degrees C. Using this approach, replication can be completed within a very short period of time (e.g., less than 3 min) without the need of resorting to pressure- or vacuum-assisted instrumentation. Serving as a proof-of-concept, we devise a mu FN that is suitable for the formation of miniaturized arrays comprising fluorescently labeled oligonucleotides and proteins on hard plastic substrates. Resultant spots are characterized by high fluorescent contrast, excellent edge definition, and uniform distribution of probes within the modified areas.
Citer cet article
Roy, E., Geissler, M., Galas, J.-C., & Veres, T. (2011). Prototyping of microfluidic systems using a commercial thermoplastic elastomer. Microfluid. Nanofluid., 11(3). https://doi.org/10.1007/s10404-011-0789-2
@article{Roy2011_113,
author = {Roy, Emmanuel and Geissler, Matthias and Galas, Jean-Christophe and Veres, Teodor},
year = {2011},
month = {1},
title = {Prototyping of microfluidic systems using a commercial thermoplastic elastomer},
journal = {Microfluid. Nanofluid.},
publisher = {SPRINGER HEIDELBERG},
volume = {11},
number = {3},
address = {TIERGARTENSTRASSE 17, D-69121 HEIDELBERG, GERMANY},
abstract = {This article describes the fabrication of microfluidic networks (mu FNs) from a commercially available (styrene)-(ethylene/butylene)-(styrene) (SEBS) block copolymer (BCP). The unique combination of hard and elastomeric properties provided by this material promotes high-throughput replication of fluidic structures using thermoforming technologies, while retaining the advantage of quick and easy assembly via conformal contact, as commonly achieved for devices fabricated from poly(dimethylsiloxane (PDMS). We employ Versaflex CL30, which is optically transparent, available at low cost (e.g., \textbackslash{}\$2.50/Lbs), and likely to be compatible with a broad range of biological species. We demonstrate excellent fidelity in replication of fluidic structures using hot embossing lithography in conjunction with a photolithographically prepared Si/SU-8 master mold. Moreover, we introduce rapid prototyping of high-quality structures using an approach that we call soft thermoplastic lithography (STPL). Thanks to the rheological characteristics of the SEBS copolymer, STPL enables thermoforming on a heated master at temperatures around 170A degrees C. Using this approach, replication can be completed within a very short period of time (e.g., less than 3 min) without the need of resorting to pressure- or vacuum-assisted instrumentation. Serving as a proof-of-concept, we devise a mu FN that is suitable for the formation of miniaturized arrays comprising fluorescently labeled oligonucleotides and proteins on hard plastic substrates. Resultant spots are characterized by high fluorescent contrast, excellent edge definition, and uniform distribution of probes within the modified areas.},
url = {http://www.dx.doi.org/10.1007/s10404-011-0789-2},
doi = {10.1007/s10404-011-0789-2},
issn = {1613-4982},
}
TY - JOUR
AU - Roy, Emmanuel
AU - Geissler, Matthias
AU - Galas, Jean-Christophe
AU - Veres, Teodor
PY - 2011
DA - 2011/01/01
TI - Prototyping of microfluidic systems using a commercial thermoplastic elastomer
JO - Microfluid. Nanofluid.
VL - 11
IS - 3
PB - SPRINGER HEIDELBERG
SN - 1613-4982
AB - This article describes the fabrication of microfluidic networks (mu FNs) from a commercially available (styrene)-(ethylene/butylene)-(styrene) (SEBS) block copolymer (BCP). The unique combination of hard and elastomeric properties provided by this material promotes high-throughput replication of fluidic structures using thermoforming technologies, while retaining the advantage of quick and easy assembly via conformal contact, as commonly achieved for devices fabricated from poly(dimethylsiloxane (PDMS). We employ Versaflex CL30, which is optically transparent, available at low cost (e.g., \$2.50/Lbs), and likely to be compatible with a broad range of biological species. We demonstrate excellent fidelity in replication of fluidic structures using hot embossing lithography in conjunction with a photolithographically prepared Si/SU-8 master mold. Moreover, we introduce rapid prototyping of high-quality structures using an approach that we call soft thermoplastic lithography (STPL). Thanks to the rheological characteristics of the SEBS copolymer, STPL enables thermoforming on a heated master at temperatures around 170A degrees C. Using this approach, replication can be completed within a very short period of time (e.g., less than 3 min) without the need of resorting to pressure- or vacuum-assisted instrumentation. Serving as a proof-of-concept, we devise a mu FN that is suitable for the formation of miniaturized arrays comprising fluorescently labeled oligonucleotides and proteins on hard plastic substrates. Resultant spots are characterized by high fluorescent contrast, excellent edge definition, and uniform distribution of probes within the modified areas.
DO - 10.1007/s10404-011-0789-2
UR - http://www.dx.doi.org/10.1007/s10404-011-0789-2
ER -